NewsInformation Center
Home>News > > 2022 New Product: Medical Face Mask Synthetic Blood Penetration Resistance Teste

2022 New Product: Medical Face Mask Synthetic Blood Penetration Resistance Teste

2022/05/18

Share: 

Share
The Medical Face Mask Synthetic Blood Penetration Resistance Tester is suitable for the determination of the penetration performance of synthetic blood of medical masks. It can be used by medical inspection departments, safety inspection departments and scientific research units.
 
principle:
The medical mask sample was supported on the test device, and 2 mL of synthetic blood was sprayed horizontally to the tested mask from a cannula with an inner diameter of 0.84 mm at a distance of 300 mm. Simulate the scene where the mask is sprayed with blood from perforated blood vessels, and observe the penetration of synthetic blood on the other side of the mask.
 
Applicable standard:
GB19083-2010: Technical requirements for medical protective masks;
YY 0469-2011: Medical surgical masks;
YY/T0691-2008: Test method for resistance to penetration of synthetic blood by medical masks of infectious agent protective equipment
 
technical parameter:
Test environment: temperature (21±5)℃; relative humidity (85±10)%
Spray distance: (300±10)mm
Nozzle diameter: Φ0.84mm, length 12.7mm
Liquid jetting speed: 450cm/s; 550 cm/s; 635 cm/s
Power supply: AC220V 50Hz
PMMA production size: 800MM-460MM-550MM
Medical Face Mask Synthetic Blood Penetration Resistance Tester
Instrument Features:
1. Convenient mask holding device;
2. Constant pressure injection device without manual adjustment;
3. The synthetic blood sampling device is easy to operate.
 
Applicable standard:
GB/T 19083-2010 Technical Requirements for Protective Covers 5.6 Synthetic Blood Penetration Barrier Performance
YY/T 0469-2011 Mask 5.5 Synthetic Blood Penetration Test
YY/T 0691-2008 "Test method for the penetration resistance of protective equipment for infectious pathogens to synthetic blood"
 
The Medical Face Mask Synthetic Blood Penetration Resistance Tester tests the medical mask samples at the liquid jet pressure corresponding to the liquid jet speed: 450 cm/s, 550 cm/s, and 635 cm/s. Record the test results of each injection speed, and give the zuigao blood pressure corresponding to the acceptable quality level limit of 4 for the medical mask.
 
After reading these, do you have a deeper understanding of the Medical Face Mask Synthetic Blood Penetration Resistance Tester? Interested customers are welcome to inquire or leave a message to us for the latest quotation!

Previous: The significance of the existence of the Shoe Slip Resistance Tester
 N e x t   : Troubleshooting of Displacement System of Tensile Tester