BACKStandards:
USA commercial respirator regulation (42 CFR part 84) European EN 143 and related respirator standards View EN 143 Compliance Report (US) View EN 143 Compliance Report (DE) JMOL (Japanese respirator standard)
Applications:
Product Information:
The Automated Filter Tester Model 8130 is designed to comply with commercial respirator mask standards around the globe and has a proven track record of durability, reliability, and minimal maintenance, meeting the demanding requirements of manufacturing and quality control environments. Whether you are looking for a stand-alone tester to check a few filters per day or need to integrate your tester in an automated, high volume production line, AFT's are up to the challenge. Specially designed aerosol generators and detectors enable highly repeatable and reproducible filter-efficiency measurements. In addition, the Model 8130 features a high degree of automation and self-diagnostics that greatly simplifies operation, increases throughput and improves overall measurement performance. As a result, The filter testers are ideally suited for QC testing.
The Model 8130 measures penetration efficiencies of filter media or masks. Values up to 99.999 percent (penetrations as low as 0.001 percent) have been realized with Emery oil at concentrations of 200mg/m³. Please note that the sensitivity for salt aerosol is less. A variety of aerosols may be used because oil aerosols are generated without heat.
Feature & Benefits
Compliance with respirator regulations
Simple, fast and automated operation
Highly consistent test results
Designed for manufacturing environments
Service and support
Thermal printer
Test media sheets
Gravimetric filter holder
Flat-media filter holder
Custom filter holders available
Technical Parameters
| Items | Parameter |
| Application | Load and quality control |
| Max Efficiency | 99.999% |
| Aerosol Type | DOP/PAO/DEHS/Paraffi/Others Oil Aerosol、Salt |
| Aerosol Generation | Atomizing |
| CMD | 0.2μm(Oil)or 0.75um(NaCl) |
| GSD | <1.6(Oil)or <1.86(NaCl) |
| Flow Rate | 15-100L/min |
| Resistance | 0-150mm H2O(0-1470Pa) |
| Particle Detect | Scatter Photometer |
| Measurement Time | 10 Sec. |
| Data Report | LCD,RS-232 |
| Operation | Independent tewster、automatic production line |
| Standard compliant | US 42 CFR part 84.EN 143.JMOL,ISO 23328-1 ISO 16900-3 |
| Power Supply | 115VAC、60Hz,10A或230VAC,50Hz,5A |
| Compressor Air | 80psig,7scfm(550kPa,198std.L/min) |
| Dimension | 70cm x 70cm x 147cm(28in, x 28in.x 58in.) |
FAQs
Q1: What is this tester used for?
A: It evaluates the filtration performance of high-efficiency filter materials.
Q2: Which materials can be tested?
A: It is suitable for compatible high-efficiency filter media and porous filtration materials.
Q3: What parameters can it measure?
A: Depending on the configuration, it can evaluate filtration efficiency, pressure drop, and airflow resistance.
Q4: Which industries use this tester?
A: It is commonly used in air filtration, cleanroom technology, HVAC, and filter manufacturing.
Q5: Why is filtration performance testing important?
A: It helps verify filter quality, assess filtration efficiency, and ensure consistent product performance.