Filter Media Tester G2000

BACK
Share

Standards:

Applications:

Complete filter test in accordance with DIN 71460 part 1 & ISO/TS 11155 part 1
Test of filter media in accordance with DIN 71460 part 1 & ISO/TS 11155 part 1
Testing of other complete filters and filter media
 

Product Information:

G2000 test rig for standard tests on motor vehicle passenger compartment filters in accordance with DIN 71460 part 1 and ISO/TS 11155-1 Palas® offers the CIF 2000 test rig with the Promo® 2000 unit for standard tests on motor vehicle passenger compartment filters in accordance with DIN 71460 part 1 and ISO/TS 11155-1.
The volume flow is automatically regulated and adjustable from 60 to 800 m3/h.
With the aid of the CIF, both the fraction separation efficiency and the burden on the complete filters or filter media are measured and evaluated.
Particle dosing for the filter test is performed with the brush generator RBG 1000, which has been internationally established for over 30 years. On the G2000, overall and fraction separation efficiency are determined with the high-resolution light scattering spectrometer Promo® 2000.
The main advantage of the Promo® 2000 systems lies in the use of fiber optic technology. Thanks to this, the sensor heads can be positioned directly at the measurement site, as a result of which line losses are minimized. With the Promo® 2000 measuring systems, reliable tests to determine the separation efficiency and burden tests can be performed across the entire measurement range for all particle sizes.
Following ISO/TS 11155-1, the test rig is also equipped with the salt aerosol generator AGK 2000. In the testing conduit, filter media up to a size of approx. 220 x 500 mm can also be tested under the conditions stated above. In order to test the influence of real ambient conditions on the separation behavior of filters, Palas®offers an upgrade to the CIF test rig with climate technology components foradjustment of the temperature between +18°C and +90°C and the relative humidity between 30% and 70%.
As an option, the test rig can be upgraded after provision of the measuring equipment for gas analysis for investigations of the adsorption and desorption dynamics following DIN 71460 part 2 and ISO/TS 11155 part 2. Automation
The CIF is equipped with a high-pressure ventilator, which can be throttled on the pressure side with infinitely variable adjustment and is frequency-controlled, and which can be automatically regulated via the FTControl filter test software for regulation of the volume flow. Furthermore, sensor data such as the volume flow, temperature, relative humidity and differential pressure at the filter are also recorded automatically during the filter test. The aerosol generators and the corona discharge can be actuated via the FTControl software.
Measurement of the fraction separation efficiency
 
Features:
Particle measurements from 200 nm
Measurement and evaluation of fraction separation efficiency and burden
Automatic data acquisition for barometer pressure, temperature, humidity, differential pressure
Temperature control (+18°C to +90°C) and moisture control (30 – 70%)
Automatic actuation of all test rig components
Automatic performance of the measurement processes
Individual programming of measurement processes for filter testing using the FTControl software
Separate measurement and analysis parts – this saves time and money, as the analysis can be performed while the measurement is still on-going
Printouts and saving of complete test records
Easy access to all data for the recorded measurement signals from the up to 6 external sensors
Low-maintenance
Easy operation
Reliable operation
The unit will reduce your operating costs
 
Technical Parameters:

Measurement range (size) 0.2 – 40 µm
Volume flow 60 m³/h – 800 m³/h (cycle operation)
Dimensions Test rig: 1000 • 2800 • 4200 mm, filter holder: 300 • 600 mm (filter and others on request)
Material Stainless steel V2A 2 mm
Temperature regulation +18°C – +90°C
Luftfeuchteregelung 30 % – 70 %
Temperature- und humidity sensor - measuring range: ‐20°C – +80°C, 0 – 100 % rel. Humidity, - accuracy: ± 0.1°C (20°C), ± 1 % RH (0 – 90 % RH), ± 2 % RH (90 – 100 % RH)
Barometric pressure gauge - measuring range: 600 – 1100 hPa, - accuracy: ± 0.10 hPa
Differential pressure gauge - measuring range: < 2500 Pa, - linearity error: < 0.2 % of the final value
Measurement of the air velocity - measuring range: 0.5 – 40 m/s, - accuracy: < +/‐ 0.05 m/s (up to 20 m/s), < +/‐ 0.08 m/s (20 – 30 m/s), < +/‐ 0.1 m/s (30 – 40 m/s)
Preconditions 3 phases, 400 V, neutral, earth connection of approx. 3 KW and provision of pressurized air max. 8 bar