G1300 High-Efficiency Filter Test Bench (Full Efficiency)

BACK
Share

Standards:

Applications:

Product Information:

The filter performance test bench adopts PLC + PC intelligent control. The software interface is clear and user-friendly, enabling fully automatic operation. After testing, the system automatically generates a report, in which all test data are included. Users can directly print or save the report with one click.The system is equipped with an airflow adjustment device for testing under different flow conditions.A multi-layer flow equalization design with a flow stabilizing device ensures uniform air velocity in the duct.

Reference Standards

IEST-RP-CC001.6-2016 HEPA and ULPA Filters

MIL-STD-282 Performance Testing Methods

IEST-RP-CC007 Testing ULPA Filters

EN1822-5

Technical Parameters

Item

Parameter

Applicable Filter Size

≤ 610 × 610 mm (larger size requires fixture change)

Test Function

Average efficiency and resistance at rated airflow

Airflow Range

300–4300 m³/h

Resistance Range

0–1000 Pa

Test Section Size

610 × 610 × 292 mm

Aerosol Type

DEHS (polydisperse), PAO (thermal generation)

Efficiency Range

40% – 99.995% @ 0.3 µm (EN1822-5)

Power Supply

380 V / 11 kW

Compressed Air

0.6 MPa, 100 L/min

Equipment Size

1100 × 900 × 1300 mm (approx.)

Core Instruments

(1) Resistance Measurement: Filter pressure drop is obtained via static pressure rings installed upstream and downstream. A high-precision imported differential pressure transmitter is used to ensure accuracy and stability.

(2) Efficiency Measurement: A high-precision domestic laser particle counting sensor is used. An isokinetic sampling probe is adopted downstream to ensure accurate, stable, fast, and effective sampling. (The sampling probe can be optionally configured according to customer requirements.)

(3) Aerosol Generation System: Laskin nozzle-type aerosol generator is used, producing polydisperse DEHS particles with stable concentration. The concentration is easy to adjust and control.

Configuration List

Category

System

Item

Specification

Quantity

Basic Section

 

Airflow System

 

Fan

6.5 kW

1 unit

Frequency Converter

Delta

1 unit

Chamber

2 mm steel plate

1 set

Nozzles 1

100 mm / 110 mm / 150 mm

1 set

Differential Pressure Gauge

Siemens QBM3120

1 pc

Fan Housing

2 mm steel plate

1 set

Airflow Adjustment

Automatic

Instrumentation

 

Particle Counter

Yaguan (0.3–10.0 μm, 8 channels)

1 unit

Aerosol Generator

Model 001

1 unit

Temperature & Humidity Sensor

Temperature: -5–55°C, Humidity: 0–100%

1 pc

Differential Pressure Gauge

Siemens QBM3120

1 pc

Diluter

Model 002

2 units

Control System

Control Cabinet

Circuit breaker, contactors, wiring, etc.

1 set

Lower-Level Control

Mitsubishi PLC

1 unit

Upper-Level Control

Industrial PC

1 unit

Test Analysis Software

 

1 set

Data Acquisition Module

 

1 set


Leave Message

Personal information

*
*
*
*

Information and comments