Product Information:
Fractional efficiency test bench main structure and trend, important parts configuration, function and important parameter setting, material selection, data processing, test bench main verification project, are based on ISO-19713-1 standard " Road vehicles - Inlet air cleaning equipment for internal combustion engines and compressors - Part 1: Fractional efficiency testing with fine particles ".
Aerosol manufacturing reference to the US standard ANS / ASHRAE 52.2-1999, fixture manufacturing reference to the European standard EN1822.
Technical Parameters
Items | Parameters | |
Test aerosol | Material | KCL solid particles |
Particle size | 0.3um-10um | |
Concentration | adjustable (≥ 10um particle concentration of about 5000-10000J / L | |
Upstream and downstream particle counter | Sampling Flow | 28.3L / min ± 5% |
Particle size | 0.3um, 0.5um, 1um, 3um, 5um, 10um | |
Particle size distribution error | indication concentration error; another count requirements are in line with national JJF 1190-2009 "dust particle counter correction norms" and on this basis, with particular emphasis on large particles (3um, 5um, 10um) metering correction. | |
Test flow rate | Flow adjustable range | 60L / min-150L / min (equivalent to the filter speed 10cm / s-25cm / s) |
Flow accuracy | ≤ ± 5% | |
Flow stability | ≤ ± 10% | |
Filter resistance measurement | Range | 0-500Pa (Please consult with other areas) |
Accuracy | ≤ ± 5% | |
Repeatability | ≤ ± 5% | |
The initial classification efficiency measurement | Applicable scope | medium,high effect filter material |
Repeatability | ≤ ± 5% |
Working condition
· Power supply: AC 220V 50Hz Power: 4KVA
· Air supply: compressed air 5-8kg / cm2
· Ambient temperature: 10o -25o RH ≤ 70% Purification grade: 10,000 level
· Covered area: test bench size: operation box 600 * 600 * 1760; sampling box 600 * 600 * 1760; air box generator box 730 * 830 * 2800 (l * w * h) Unit: mm
· Filter material sample size: test bench effective detection area: 100cm2 round
Components
· KCL aerosol generator
· Mixer
· Filter on the next fixture
· Upstream and downstream particle isokinetic sampler
· Upstream and downstream particle counters
· Flow system
· Electrical, computer control system
· Test results output section