Search keywords:

product name, product type, model number,
test method, manufacturer, technique, application

vertical flame test chamber

BACK
Share

Standards:

ASTM D6413, CALIF TB117, DOC-FF 3/71, 16CFR Parts1615/1616, FTMS 191-5903, CPAI 84

Applications:

The vertical burning of textiles is suitable for all types of fabrics and their products. Test method applicable to the burning performance of the bottom edge of the vertical textile specified in GB5455-2014 standard.

Product Information:

The Vertical Flammability Chamber, designed for American Standards, measures the vertical flame spread for children's sleepwear, fabrics, other textile materials or resilient filling materials used in upholstered furniture.

Application:

The vertical burning of textiles is suitable for all types of fabrics and their products. Test method applicable to the burning performance of the bottom edge of the vertical textile specified in GB5455-2014 standard.

Features:

Gas pipeline system special designed, low space occupied, and convenience to move;

Exhaust vents at the bottom and top of test chamber ensure good ventilation and steady flame;

LED displayer shows the igniting time, afterflame time and afterglow time, with high working efficient and the data more accuracy;

A stainless steel construction, large glass-viewing window;

Excellent reliability and minimum maintenance;

Purpose-designed test chamber.

Standards:

ASTM D6413. CALIF TB117. DOC-FF 3/71. 16CFR Parts1615/1616. FTMS 191-5903. CPAI 84

Parameter:

Item Parameter
Inner Size About 330 × 330 × 765 mm
Windows Tempered glass observation window
Exhaust Holes 16 pcs proof holes, 6 pcs each side (total 12 pcs)
Exhaust Diameter 12.5 mm
Proof Hanging Clamp Located 17 mm above the highest point of the igniter nozzle
Diameter of the Igniter Nozzle 11 mm
Angle About the Head and Vertical Line 25°
Inlet Gas Pressure of the Igniter 17.2 kPa ± 1.7 kPa
Ignition Time Accurate to 0.05 s
Gas Source Industrial-grade propane, butane, or propane/butane mixed gas. When the sample is pretreated according to 7.3 in GB 5455-2014. methane gas with a purity of not less than 97% is selected.
Sample Size 300 × 89 mm, five horizontal and vertical
Ambient Temperature -10°C to 30°C
Power Supply Voltage 220 V ± 10%, 50 Hz
Power Less than 100 W
Flame Time 0–99 min 99 s
Flame Time Accuracy ±0.01 s
Afterglow Time Longest 0–99 min 99 s
Blue Flame Height 15–175 mm, with flame height scale
Ignition Time Any setting (can be preset)

vertical flammability tester

Leave Message

Personal information

*
*
*
*

Information and comments