Search keywords:
product name, product type, model number,
test method, manufacturer, technique, application
vertical flame test chamber
BACKStandards:
ASTM D6413, CALIF TB117, DOC-FF 3/71, 16CFR Parts1615/1616, FTMS 191-5903, CPAI 84
Applications:
The vertical burning of textiles is suitable for all types of fabrics and their products. Test method applicable to the burning performance of the bottom edge of the vertical textile specified in GB5455-2014 standard.
Product Information:
The Vertical Flammability Chamber, designed for American Standards, measures the vertical flame spread for children's sleepwear, fabrics, other textile materials or resilient filling materials used in upholstered furniture.
Application:
The vertical burning of textiles is suitable for all types of fabrics and their products. Test method applicable to the burning performance of the bottom edge of the vertical textile specified in GB5455-2014 standard.
Features:
Gas pipeline system special designed, low space occupied, and convenience to move;
Exhaust vents at the bottom and top of test chamber ensure good ventilation and steady flame;
LED displayer shows the igniting time, afterflame time and afterglow time, with high working efficient and the data more accuracy;
A stainless steel construction, large glass-viewing window;
Excellent reliability and minimum maintenance;
Purpose-designed test chamber.
Standards:
ASTM D6413. CALIF TB117. DOC-FF 3/71. 16CFR Parts1615/1616. FTMS 191-5903. CPAI 84
Parameter:
| Item | Parameter |
|---|---|
| Inner Size | About 330 × 330 × 765 mm |
| Windows | Tempered glass observation window |
| Exhaust Holes | 16 pcs proof holes, 6 pcs each side (total 12 pcs) |
| Exhaust Diameter | 12.5 mm |
| Proof Hanging Clamp | Located 17 mm above the highest point of the igniter nozzle |
| Diameter of the Igniter Nozzle | 11 mm |
| Angle About the Head and Vertical Line | 25° |
| Inlet Gas Pressure of the Igniter | 17.2 kPa ± 1.7 kPa |
| Ignition Time | Accurate to 0.05 s |
| Gas Source | Industrial-grade propane, butane, or propane/butane mixed gas. When the sample is pretreated according to 7.3 in GB 5455-2014. methane gas with a purity of not less than 97% is selected. |
| Sample Size | 300 × 89 mm, five horizontal and vertical |
| Ambient Temperature | -10°C to 30°C |
| Power Supply Voltage | 220 V ± 10%, 50 Hz |
| Power | Less than 100 W |
| Flame Time | 0–99 min 99 s |
| Flame Time Accuracy | ±0.01 s |
| Afterglow Time | Longest 0–99 min 99 s |
| Blue Flame Height | 15–175 mm, with flame height scale |
| Ignition Time | Any setting (can be preset) |