Search keywords:

product name, product type, model number,
test method, manufacturer, technique, application

Vacuum Cleaner Air Performance Testing Equipment

BACK
Share

Standards:

Applications:

Air performance testing of complete vacuum cleaners

Performance evaluation of handheld vacuum cleaners

Airflow and suction testing of vacuum cleaner motors

Product development and performance benchmarking

Type testing and routine inspection in manufacturing

Verification testing by third-party laboratories

Product Information:

The Vacuum Cleaner Air Performance Testing Equipment (Type A Pressure Equalization Chamber) is designed to measure the airflow performance of vacuum cleaners and vacuum cleaner motors with airflow below 40 L/min. You use this system to evaluate key air performance parameters under standardized conditions defined by Type A pressure equalization chamber requirements. Manufactured in compliance with international and national standards, the equipment provides accurate, repeatable, and comparable test results for airflow, suction power, and efficiency. Test data can be automatically recorded and exported via USB, making it suitable for both production and laboratory environments.

Standards

IEC 60312-1: Vacuum Cleaners for Household Use – Methods for Measuring the Performance – Part 1: Dry Vacuum Cleaners

GB/T 20291.1: Household and Similar Electrical Appliances – Vacuum Cleaners – Part 1: Methods for Measuring Performance

IEC 62885-2: Surface Cleaning Appliances – Part 2: Dry Vacuum Cleaners for Household or Similar Use – Methods for Measuring the Performance

Type A Pressure Equalization Chamber Design as specified in IEC and GB standards

Features

You can perform airflow testing using a standardized Type A pressure equalization chamber

Stepless electric throttle valve allows precise airflow adjustment

Industrial control computer ensures stable data acquisition and processing

Supports simultaneous measurement of electrical and air performance parameters

Suitable for both complete vacuum cleaners and vacuum motors

USB data export simplifies test record storage and reporting

Compact layout with professional laboratory-grade construction

Technical Parameters

Item Specification
Adjustment Method Electric throttle valve with stepless speed regulation
Pressure Chamber Dimensions 460×460×250 mm
Control Mode 17-inch industrial control computer display
Tester Type Vacuum cleaner parameter tester
Test Voltage AC/DC 10–300V, accuracy: 0.5%
Test Current AC/DC 0.1A–20A, accuracy: 0.5%
Test Items Voltage, current, power, vacuum level, air volume, suction power, efficiency
Vacuum Gauge Range: -50–0 kPa, accuracy: ±0.075%/±0.05%
Equipment Power Supply 220V 50Hz, 1.5KW
Equipment Dimensions 1850×680×1680 mm

Accessoriess

(1) Type A pressure equalization chamber

(2) Electric throttle valve assembly

(3) Vacuum pressure measurement module

(4) Integrated electrical parameter tester

(5) USB data export interface

Test Procedures

1.You install the vacuum cleaner or motor under test onto the test interface.

2.Connect electrical and airflow measurement components securely.

3.Select test parameters and operating mode on the industrial control computer.

4.Adjust airflow using the electric throttle valve according to the standard.

5.Start the test and allow the system to stabilize.

6.The system automatically records voltage, current, airflow, vacuum pressure, and calculated performance values.

7.the completed test data via USB after test completion.

Conclusion

The Vacuum Cleaner Air Performance Testing Equipment with Type A pressure equalization chamber provides you with a precise and standardized solution for airflow performance evaluation. By combining accurate airflow control, comprehensive parameter measurement, and compliance with IEC and GB standards, the system supports reliable testing for manufacturers and professional testing institutions.

FAQ

1. What types of products can be tested with this equipment?

You can test handheld vacuum cleaners, compact vacuum cleaners, and vacuum cleaner motors with airflow below 40 L/min.

2. What is the role of the Type A pressure equalization chamber?

It ensures stable airflow conditions and standardized measurement as required by IEC and GB performance testing standards.

3. How is airflow adjusted during testing?

Airflow is controlled using a stepless electric throttle valve for precise regulation.

4. Which parameters are measured during the test?

The system measures voltage, current, power, vacuum pressure, airflow, suction power, and efficiency.

5. How are test results stored and exported?

Test data is automatically recorded by the control system and exported via USB.

6. Is this equipment suitable for laboratory certification testing?

Yes, it complies with IEC 60312-1. IEC 62885-2. and GB/T 20291.1. making it suitable for laboratory and certification use.


Leave Message

Personal information

*
*
*
*

Information and comments