Circular cut tester G-9806
BACKStandards:
Applications:
Product Information:
The test specimen is placed under a circular cutting wheel equipped with a counter and subjected to a certain pressure. The rotation of the circular cutting wheel and the movement of the test specimen are used to evaluate the cut resistance of special protective gloves.
Main Functions
Testing the cut resistance performance of protective gloves and shoe uppers according to standards such as EN388.
Reference Standards
EN388:2016. GB/T20991-2007. ISO20344-2004
GB/T17622-2008 "Insulating Gloves for Live Work"
AQ6102-2007 "Acid and Alkali Resistant Gloves"
GB24541-2009 "Protective Gloves against Mechanical Hazards"
GA614-2006 "Police Cut-Resistant Gloves"
Technical Specifications
Blade load: (5 ± 0.5) N and (20 ± 0.5) N
Motion stroke: 50 mm
Cutting speed: maximum sinusoidal cutting speed 8 ± 2 cm/s
Blade requirements: circular blade diameter (45 ± 0.5) mm, thickness (0.3 ± 0.03) mm
Total cutting angle: 30°–35°; blade hardness: tungsten steel 700–720 HV
Specimen size: 100 × 60 mm
Counter range: 0–999.999
Dimensions: 580 × 160 × 430 mm
Weight: 60 kg
Power supply: AC 220V, 10A
Standard Accessories
Test machine × 1
Test frame × 2
Circular blades × 5
Power cord × 1
User manual × 1
Delivery note × 1
Packing list × 1
Instrument Features
Color PLC integrated display control box with menu-driven operation mode;
Radial movement without swing, smooth operation without jump or vibration;
Precision high-grade motor drive, stable operation, low noise;
Jog function adjustment, automatic knife holder reset;
Tungsten steel blade with hardness, standard friction head weights;
Replaceable specimen table, capable of multi-position testing;