AAA Steady-State Solar Simulator for PV Modules
BACKStandards:
Applications:
Used for performance testing and real-time MPPT (Maximum Power Point Tracking) monitoring of perovskite-silicon tandem photovoltaic modules under high-precision temperature-controlled conditions and AAA-class steady-state solar illumination.
Product Information:
1.Equipment Overview
AAA Steady-State Solar Simulator for PV Modules is a testing instrument designed to simulate natural sunlight under controlled, steady-state conditions. It provides uniform and stable illumination with AAA spectral match, spatial non-uniformity, and temporal instability classifications, enabling accurate measurement of photovoltaic (PV) module performance, including maximum power output, current-voltage (I-V) characteristics, and conversion efficiency.
2.Equipment Display

3.Main Technical Specifications and Principles
3.1 Simulated Light Source
3.1.1 Spectral Match:
The spectral irradiance distribution complies with the requirements of IEC 60904-9 (AM1.5 standard solar spectrum).
3.1.2 Spectral Range:
300–1200 nm
3.1.3 Total Irradiance Intensity:
1000 W/m²
3.1.4 Irradiance Adjustment Range:
100 W/m²–1200 W/m²
3.1.5 Irradiance Non-Uniformity:
≤ ±2% (Class A)
3.1.6 Irradiance Instability:≤ ±1%
3.1.7 Light Irradiation Direction:Vertical downward direct illumination
3.1.8 Light Source Warm-Up Time:≤ 10 s
3.1.9 Real-Time Irradiance Monitoring:
Equipped with a built-in reference solar cell and irradiance sensor to monitor irradiance in real time and synchronously record measurement data.
3.1.10 AM1.0 Capability:
The system supports AM1.0 solar spectrum simulation.
3.1.11 Illumination Area:
2500 mm × 1400 mm
3.1.12 Light Source Service Life:
10.000 hours
3.1.13 Light Source Cooling Method:
Air cooling
3.1.14 Operating Time:
The equipment can operate continuously for more than 24 hours.
3.1.15 Light Source Control System:
Controlled by a touch screen and PLC system, supporting programmable irradiance settings, test program presets, light source status monitoring, and fault alarms. Interfaces are reserved for integration with the chamber temperature control system and measurement system.
3.2 Temperature Control Chamber
3.2.1 Chamber Structure:
The chamber is constructed with insulated and light-shielding foam panels combined with sheet metal, providing excellent protection and thermal insulation performance. The inner chamber adopts a multi-layer design to ensure effective heat preservation during long-term high-temperature testing.
3.2.2 Heating System:
Equipped with U-shaped 304 stainless steel nickel-chromium electric heating tubes, using SSR (Solid State Relay) contactless control for rapid and uniform heating.
3.2.3 Chamber Temperature Range:20°C–90°C
3.2.4 Module Testing Temperature Range:25°C–80°C
3.2.5 Sample Rack:
Designed for parallel placement of samples, compatible with sample sizes up to 2500 × 1400 mm, and supports quick sample installation, clamping, and fixation.
3.2.6 Temperature Uniformity:≤ ±1°C
3.2.7 Temperature Stability Accuracy:±0.3°C
3.2.8 Temperature Display Resolution:0.01°C
3.2.9 Heating Rate:
The chamber can heat from 25°C to 90°C within ≤30 minutes (under no-load conditions).
3.2.10 Cooling Rate:
The chamber can cool from 90°C to 25°C within ≤30 minutes (under no-load conditions).
3.2.11 Temperature Control Method:
Adopts intelligent PID temperature control with multi-loop independent control, supporting programmable temperature rise, holding, and cooling processes with automatic execution.
3.2.12 Temperature Sensor Configuration:
Equipped with PT100 platinum resistance temperature sensors distributed in the chamber working area and on the sample surface for real-time temperature acquisition and feedback.
3.3 Measurement Range
3.3.1 Effective Test Area:2500 mm × 1400 mm
3.3.2 Effective Test Range:5 W–1000 W, supporting photovoltaic modules with corresponding maximum power output within the test area.
3.3.3 Measurement Voltage Range:0 mV–300 V (Resolution: 1 mV)
3.3.4 Measurement Current Range:0 mA–20 A (Resolution: 1 mA)
3.4 Measurement Accuracy
3.4.1 Voltage Measurement Accuracy:0.3% FS + 5 dgt
3.4.2 Current Measurement Accuracy:0.3% FS + 5 dgt
3.5 Measurement Method:Four-wire measurement method
3.6 Measurement Parameters:Isc, Voc, Pmax, Vm, Im, FF, EFF, Temperature, Rs, Rsh
3.7 Scanning Time:Complete I-V curve scanning time ≤ 500 ms per measurement
3.8 Sampling Points:≥ 8000 sampling points for a single I-V curve
3.9 Multi-Channel Testing Capability:Compatible with multiple small photovoltaic modules for simultaneous testing, with 12 independent test channels.
3.9 Test Condition Correction
3.9.1 Automatic Irradiance Compensation
3.9.2 Automatic Temperature Compensation
3.10 Temperature Measurement
3.10.1 Temperature Compensation and Display:
Provides real-time temperature compensation and temperature display during testing.
3.10.2 Built-in Non-Contact Infrared Temperature Measurement:
Equipped with a built-in non-contact infrared temperature sensor for real-time temperature monitoring of the test sample.
3.11 Test Results
3.11.1 Voice Reporting and Voice Prompt:
The system provides voice reporting of test results and voice prompts during operation.
3.11.2 Test Time and Graphical Parameter Display:
Displays test time and graphical test parameters, including the I-V characteristic curve.
3.12 Test Report
3.12.1 I-V Curve Display and Recording:
The current operation interface displays and records the I-V characteristic curve.
3.12.2 Data Storage:
All main test parameters of photovoltaic modules can be saved to a designated file on the hard disk.
3.12.3 File Naming:
The designated data files can be named according to user requirements.
3.13 Data Summary and Printing
3.13.1 Data Summary:
Data can be summarized according to a specified time period or generated at any time.
3.13.2 Excel Format Printing:
Test data can be exported and printed in Excel format, including cumulative output of I-V characteristic curves.
3.14 Dedicated Software
3.14.1 Temperature Compensation Coefficient Input
3.14.2 Date, Name, Row and Column Number Input
3.14.3 Automatic Serial Number Increment Setting
3.14.4 Defective Product Parameter Range Setting
3.14.5 Centralized Parameter Control
3.15 MPPT System
3.15.1 System Design:
The system adopts switch-mode PWM technology, full-bridge phase-shift soft-switching technology, and ARM + DSP dual-CPU control architecture,16-bit High-Speed ADC Sampling.
3.15.2 Applicable Standards:Complies with EN 50530. Sandia, and CGC-GF004 standards; CE certified.
3.15.3 Input Voltage:220 V, 50 Hz
3.15.4 Output Voltage Range:0–300 V
3.15.5 Output Current Range:0–30 A
3.15.6 Output Operating Modes:
Supports constant voltage (CV), constant current (CC), constant power (CP), and constant internal resistance modes. Voltage, current, and power can be adjusted from 0–100% of the rated value.
3.15.7 Voltage and Current Regulation Accuracy:
Voltage regulation accuracy: ≤ ±0.3% FS
Current regulation accuracy: ≤ ±0.5% FS
3.15.8 Measurement Accuracy:
Voltage: ±0.2% FS ± 2 dgt
Current: ±0.3% FS ± 2 dgt
3.15.9 System Functions:
Capable of simulating I-V characteristic curves of thin-film photovoltaic cells, perovskite solar cells, standard crystalline silicon photovoltaic cells, and high-efficiency crystalline silicon photovoltaic cells. Supports user-defined I-V curve simulation.
3.15.10 Fill Factor and I-V Characteristic Simulation:Supports fill factor (FF) setting and simulation of I-V characteristics under different irradiance and temperature conditions.
3.15.11 MPPT Testing Function:Supports static and dynamic MPPT testing, with real-time display of the MPPT operating point on the host computer.
3.15.12 Memory Storage:Stores 9 groups of data, with voltage and current parameters saved in each group for direct recall.
3.15.13 LCD Display:Displays voltage, current, power, and operating time.
3.15.14 Standard Communication Interfaces:Equipped with RS232. RS485. USB, LAN, and analog control interfaces.
3.15.15 System Protection:Provides over-voltage protection (OVP), over-current protection (OCP), over-temperature protection (OTP), and short-circuit protection. Supports voltage limit (V-LIM) and current limit (I-LIM) settings; output will automatically stop when limits are exceeded.
4. Complete Equipment Configuration
4.1 Temperature Control Test Chamber:One unit
4.2 Simulated Light Source:One set
4.3 Light Source Control Cabinet:One unit
4.4 Industrial Computer:One unit
4.5 MPPT Measurement System:One set
4.6 Dedicated Measurement Software:One set
4.7 Reference Solar Cell:
Used for irradiance calibration, compensation, uniformity measurement, and light intensity compensation.