NewsInformation Center
Home>News > > Diaper leakage tester standards

Diaper leakage tester standards

2024/04/17

Share: 

Share
  The three elements of permeability: slip infiltration, backflow, and leakage.

  Slippery infiltration: refers to the volume of test solution that is not absorbed when passing through the surface of an inclined specimen.

  Infiltration amount: The quality of the test solution that is absorbed by the sample and returned to the surface layer under a certain pressure.

  Leakage amount: The quality of the test solution that passes through the anti leakage bottom film under a certain pressure after the sample absorbs a certain amount of test solution.

  Applicable standards:

  GB/T 28004-2011 Diapers (Sheet/Pad)

  GB/T 8939-2008 Sanitary napkins (including sanitary pads)

  QB/T 2493-2000 diapers (piece/pad)

  After absorbing a certain amount of test solution, the sample of the diaper leakage tester passes through the quality of the test solution through the anti leakage bottom film under a certain pressure.

  Technical indicators:

  1. Test slope angle: adjustable at 10 ° and 30 °

  (Diapers 30 ° ± 2 °, sanitary napkins 10 ° ± 1 °)

  2. Discharge funnel: 150mL

  3. Standard pressure block with a diameter of 100mm: 1.2kg

  Configuration list:

  1 tester

  2. One beaker (500ml)

  3. One measuring cylinder (10ml, 100ml) each

  4. Four stainless steel clips

  5. One standard pressure block weighing 1.2kg

Previous: Diaper absorption speed tester parameters