Glow Wire testing Apparatus Test procedures
2017/10/09
Glow Wire testing Apparatus is suitable for lighting equipment, low-voltage electrical appliances, electrical instruments, and other electrical and electronic products and non-metallic materials and parts for household electrical appliances, such as: switch shell, relay socket. Wide range of applications. It can be applied to the production enterprises, quality inspection departments, institutions and research institutes and other institutions.
Standards:
1. IEC 60695-2-10 Fire hazard testing -- Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
2. VDE 0471 Fire hazard testing; part 2: test methods; glow-wire test and guidance

Glow Wire Tester Test Procedures
1、make connect to power switch in burn cases
2、Press the "reset" button, set the burning time according to the standard requirement
3、Press the heat button access to current, a clockwise to adjust the heating power knob "current regulation"
4、After stable temperature, press the "left" button, the car will go on. When the sample into contact with hot wire, at this point the car stopped on the left, namely the instrument for timing, hot to preset time arrives, rack back automatically, trial when sample a flame, press the "residual flame pause," flame dies should press the "burning" suspended, if you want to stop the test halfway, can press the "stop" button
Standards:
1. IEC 60695-2-10 Fire hazard testing -- Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
2. VDE 0471 Fire hazard testing; part 2: test methods; glow-wire test and guidance

Glow Wire Tester Test Procedures
1、make connect to power switch in burn cases
2、Press the "reset" button, set the burning time according to the standard requirement
3、Press the heat button access to current, a clockwise to adjust the heating power knob "current regulation"
4、After stable temperature, press the "left" button, the car will go on. When the sample into contact with hot wire, at this point the car stopped on the left, namely the instrument for timing, hot to preset time arrives, rack back automatically, trial when sample a flame, press the "residual flame pause," flame dies should press the "burning" suspended, if you want to stop the test halfway, can press the "stop" button
Previous: Heat Resistance Contact Tester Technical Parameters