Heat Resistance Contact Tester Technical Parameters
2017/10/09
Heat Resistance Contact Tester Application:
Heat Resistance Contact Tester is mainly used to test fire clothes, thermal protective gloves, or similar thermal protection material against thermal heat contact heat capacity.
Heat Resistance Contact Tester Technical Parameters:
1. High temperature heating (Φ25.2mm) configuration with sensitive temperature sensor and temperature setting device to achieve the heating body room temperature to 500 ℃ within the arbitrary set;
2. Heating body covered insulation material, effective insulation, to avoid that the test results were distorted, which caused by cooling significantly.
3. Heating block above the configuration weight to provide 49N contact force;
4. Anodized aluminum heat (temperature) meter (Φ25mm, 5mm), measurement accuracy ± 0.1 ℃;
5. Using the heat (temperature) meter to carry the sample to rise to contact the heating body, the heat (temperature) meter movement speed 5mm / s, control precision;
6. One-button test, LED display shows the sample start temperature, real-time test temperature, and the sample up to 10 ℃ when the critical time, the display accuracy of ± 0.1s.
7. Size: 800 × 50 × 550mm
8. Power supply: 230V, 50Hz
Previous: Detailed Technical Data of European Standard Rotatory Drum Dryer
N e x t : Glow Wire testing Apparatus Test procedures