Operation Method Of Fabric Air Permeability Tester
2018/03/23
The air permeability tester of fabric is the main testing tool for testing the breathability test of fabric. It mainly tests the air permeability and comfortable performance of fabric, and guarantees the quality and health of textile clothing.

Operation Method Of Fabric Air Permeability Tester:

Operation Method Of Fabric Air Permeability Tester:
1. Prepare samples and cut them into specified sizes as required.
2. Check the calibration instrument.
3. Open the power switch, conduct the test parameter setting for the control panel interface, and enter the test preparation interface after setting.
4. Install the sample, the sample in the test area, holding on the sample frustum of a cone, the test location to avoid edge and crease, adoption of a certain tension when gripped sample make samples without deformation. To prevent air leakage, gasket on the low-pressure side of the sample. The gasket can be used for the rubber sheet of 2.5mm, hardness 65 ~ 70IRHD. If there is a difference between the two sides of the fabric, test the test surface.
5. Press the start button, and the instrument begins to test automatically. The suction fan starts the air through the sample. When the pressure drop is close to the regulation value, the air flow can be recorded automatically.
6. Test finished, press the test head press plate, release the clamping sample. Place the test sample next to the test area, press the test head to press the test sample, press the start button, and the instrument will be tested again.
7. Repeat the above operation until a set of samples are completed. Under the same conditions, repeat the test at different parts of the same sample at least 5 times.
8. After the test, the test panel can be used to query, and the test results can be searched and viewed in turn, and the test average is displayed. If the air leakage occurs, the air leakage can be measured and the value is removed from the data.
9. Press the test pressure plate to release the clamping device to avoid fatigue. Close the instrument power supply and remove the power plug to cover the instrument.